 Section 455 - Public Bathrooms and Restrooms

 


455.01 Public Bathroom Defined. 
A bathroom or restroom located in a non-residential building or in a residential building, but not within a dwelling unit.

455.02 Construction. 

Subd. 1    Materials.  All public bathrooms shall be constructed of materials which are impervious to moisture, bacteria, mold or fungus growth.  The floor to wall joints shall be constructed to provide a sanitary cove with a minimum radius of 3/8 inch.  The entire floor shall be ceramic tile.  All wall surfaces within 24 inches of a water closet or urinal shall be ceramic tile to a height of 48 inches.

Subd. 2    Plumbing, Ventilation, and Equipment.  All public bathrooms shall be provided with mechanical ventilation with two cfm per square foot of area, a minimum of 15 foot candles of illumination, a hand washing sink equipped with hot and cold running water under pressure, a floor drain, a sanitary towel dispenser, a toilet tissue dispenser and a refuse receptacle.

455.03 Maintenance.  Floors, walls, ceilings, water closets, hand washing sinks and urinals shall be kept in good repair and maintained in a clean sanitary condition.  Sanitary hand cleaning agents, sanitary towels and toilet tissue shall be provided at all times.  Refuse receptacles shall be emptied and refuse collected as required.

History:  Ord 436 codified 1970; amended by Ord 436-A1 7-21-82; Ord 2000-07 7-5-00